Dolphinmed delivery high precious veterinary anaesthesia equipment system . It is suitable for animal hospital, pet clinic and animal laboratory. This technical index of animal anaesthesia machine can meet the needs of general anesthesia and medical research on mice, dogs, cats, rabbits, monkeys, pigs, sheep and other animals in animal laboratory. 


Product introduction

Compact light-weight and portable, could be transported by pull-rod case, put on table and assembly on the trolley.

Suitable for small animals, Non-breathing circuit(Jackson or Bains Absorber) is available

Selectatec-bar and quick change vaporizer mounting device

Professional airtight breathing circuit design, provide the stable gas anesthesia, save anesthesia gas consumption, to ensure a clean operating room and laboratory environment.

External and reusable soda lime canister, easily watch and replace soda lime.

With Oxygen flush function to ensure that clinical anesthesia demand and

Oxygen supply demand.

Anaesthesia CO2 absorber assembly has no dead angle design, fast anesthesia, short recovery and high precision. The CO2 absorber supports both open

loop and closed loop anaesthesia design and provides independent access .

Provide a special Pop-Off  valve,Occlusion design, it can  connected to the exhaust gas recovery system and provide a continuous 2 cmH2O negative pressure for the reaspirato airbag ,reducing valve to prevent pressure to hurt the animal, ensure the animal safety .  

Provides an accurate oxygen flow meter with a display range of 0 to 4LPM

Vaporizer: the output concentration is not affected by the change of flow, pressure and temperature, accurate and reliable, equipped with safety locking device to prevent

anesthetic leakage. Isoflurane,sevoflurane and halothane vaporizer are optional.

The hard aluminum solid shell is used, and the surface sanding treatment is

adopted, so that the cleaning and disinfection are more convenient.

Visible inspiration and expiration valve

Specifically designed to accomodate low flow anesthesia 

Technical Specification

Application

0.5-100kg animal

Ventilation mode

Closed,half-closed,half-open

Tidal volume

10-2000ml

Oxygen source pressure

0.25~0.65Mpa

Airway pressure scope

030~60CMH2O

Flow Control

0-4L/min

Oxygen Flush

35L/min~75L/min

Pop adjust scope

Directs the waste anesthetic gas from the machine to a scavenging system. In the completely open position, the pop-off valve will release pressure at 2 cm H2O, while maintain a constant passive volume in the breathing bags. 

Inspiration impedance

≦0.6Kpa

Expiration impedance

≦0.6Kpa

Absorption tank capacity

700ml

Monitoring

Airway pressure,Gas source pressure monitoring

I:E

As doctor need

BPM

As doctor need

Configuration list

Main unit

1

Include the flowmeter,CO2 absorber,selectatec bar,chassis,oxygen flush

Anesthesia Vaporizer

1

Isoflurane,Halothane,Sevoflurane, Enflurane

With temperature, flow and pressure compensation

Breathing circuit

1


Gas airbag0.5L,1L,3L

3


Reusable Silicon pipeline

1

Ф22×1000

Oxygen hose

1


Y-connector

1

With pressure differential sampling connector

Trolley

1


Regulator

Optional


Anesthesia ventilator

Optional

Model:DAV80V or DAV60V

Anesthesia monitor

Optional

Anesthesia monitor

Non-Breathing circuit

Optional


Veterinary Mask

Optional

DAM80

Laryngoscope

Optional


Endotracheal intubation

Optional


Exhaust gas recovery tank

Optional

DE0602